How to Configurations RBS Parameter Single RAN 2G & 3G

Konfigurasi cabinet RBS 900 (UL) , 1800 (OL1) , 3G SingleRAN

MASTER RBS 2G 900 (UL)

Koneksi EC port di SHU 02 01:
B1 : RBS 2G 900 (Master)
A5 : RBS 2G 1800 (Secondary)
A6 : RBS 3G (Secondary)
** Untuk SHU 01 01 , B1 diganti dengan Ain
I. Setting 2G 900 (UL)
1. Configuration – Define – Node Paremeter
2. Setting Node
- Support system control = True
- Hub Positon = B1
- Logical Name = Tidak mandatory untuk diisi, dikosongi juga tidak masalah
3. Add Node, Hub Address = A5
4. Add Node, Hub Address = A6
5. Klik OK, Cek tampilan di System OMT
6. Selanjut nya Install IDB
II. Setting 2G 1800 (OL1)
1. Configuration – Define – Node Paremeter
2. Setting Node
- Support system control = False
- Hub Positon = A5
3. Klik OK, Cek tampilan di System OMT
4. Install IDB
III. Setting 3G
1. Pilih menu – Containment (MOM based)
2. Di MO Tree pilih EquipmentSupportFunction=1
- Ubah supportSystemControl = false
3. Pilih Equipment=1
4. Klik Mo, pilih Add
- MO Class = ExternalNode, ID = 1, informationOnly = false (tidak usah diganti
5. Klik Add – Close
6. Di MO Tree, pilih ExternalNode = 1 , Klik MO – Add
- MO Class = EcPort, ID = 1, hubPosition = B1
7. Klik Add – Close
8. Di MO Tree pilih Equipment =1 -> Subrack=1 -> Slot=1 -> PlugInUnit=1 -> EcPort=1
- hubPosition = A6
9. Klik Apply
10. Create CV
Untuk settingan 3G master hampir sama seperti diatas!!!

Konfigurasi cabinet RBS 900 (UL) , 1800 (OL1) , 3G SingleRAN

MASTER RBS 3G

Koneksi EC port di SHU 02 01:
A5 : RBS 2G 900 (Secondary)
A6 : RBS 2G 1800 (Secondary)
B1 : RBS 3G (Master)
** Untuk SHU 01 01 , B1 diganti dengan Ain

I. Setting 2G 900 (UL)
1. Configuration – Define – Node Paremeter
2. Setting Node
- Support system control = False
- Hub Positon = A5
- Logical Name = Tidak mandatory untuk diisi, dikosongi juga tidak masalah
3. Klik OK, Cek tampilan di System OMT
4. Install IDB
II. Setting 2G 1800 (OL1)
1. Configuration – Define – Node Paremeter
2. Setting Node
- Support system control = False
- Hub Positon = A6
3. Klik OK, Cek tampilan di System OMT
4. Install IDB
III. Setting 3G
1. Pilih menu – Containment (MOM based)
2. Di MO Tree pilih EquipmentSupportFunction=1
- Pilih supportSystemControl = true
3. Pilih Equipment=1
4. Klik Mo, pilih Add
- MO Class = ExternalNode, ID = 1, informationOnly = false (tidak usah diganti)
5. Klik Add
6. Ganti ID = 2 , Klik Add - Close
7. Di MO Tree, pilih ExternalNode = 1 , Klik MO – AddClass = EcPort, ID = 1, hubPosition = B1
8. Klik Add
9. Ganti ID=2 , hubPosition = A5
10. Klik Add – Close
11. Ulangi step 7 – 10 untuk di ExternalNode = 2
- EcPort ID = 1, hubPosition = B1
- EcPort ID = 2, hubPosition = A6
12. Create CV


=============================FINIS======================================























EmoticonEmoticon